


HVAC Repair in the Bronx, NY
Boiler repair, radiator repair, furnace repair, AC repair and window AC repair in West Farms, Crotona Park East, East Tremont, Van Nest and across the Bronx.
Heating and Cooling Repair in the Bronx
Ephraim Heating & Air repairs boilers, radiators, furnaces, central air conditioning and window and through-wall units across the Bronx.
When the heat goes out, the cause is usually one part. On a steam or hot water boiler it is a low water cutoff, a water feeder, a circulator pump, a zone valve, a clogged burner nozzle or a radiator vent. On a gas furnace the usual suspects are the igniter, flame sensor, pressure switch and blower; see furnace repair in the Bronx.
When the cooling stops in July, a central AC system usually has a failed capacitor, a burned contactor, a seized fan motor or a clogged drain. A window or through-wall unit usually has a dirty coil, a frozen front coil, a bad capacitor or a blocked drain pan; see window AC repair.
Boiler Not Firing in Cold Weather?
A boiler that has stopped with the building going cold, water on the boiler room floor or a relief valve spraying is an emergency call. The common causes are a burner in lockout, low water in a steam boiler, a waterlogged expansion tank or a seized circulator.
Details are on the emergency boiler repair page, or call (914) 573-5224.
Boiler, Furnace and AC Repairs
- Boiler Repair in the Bronx
- Steam and hot water boilers, gas or oil: circulators, zone valves, low water cutoffs, water feeders, expansion tanks, burners and controls, plus radiator vents, valves and baseboard.
- Emergency Boiler Repair in the Bronx
- Boilers that will not fire, lock out, leak, overfill or keep shutting off in cold weather.
- Furnace Repair in the Bronx
- Gas furnaces in closets, cellars and utility rooms: igniters, flame sensors, pressure switches, inducer motors, blowers and control boards.
- AC Repair in the Bronx
- Central air conditioning and ductless systems: capacitors, contactors, condenser fan motors, frozen coils and clogged condensate drains.
- Window AC Repair in the Bronx
- Window air conditioners, through-wall units and PTACs that leak, freeze, trip breakers or blow warm air.
Bronx Buildings and the Heat They Run On
West Farms and East Tremont are made up mostly of five and six story tenements. In a walk-up heated by a steam boiler, age brings the same problems: vents that stick shut, mains that sag and bang, sight glasses that clog and low water cutoffs that hold the burner off. The pitch, the vents and the water level are where that top-floor trouble usually shows up.
Crotona Park East and West Farms also have many newer townhouses and apartment buildings. Where those run on a hot water boiler with baseboard or a gas furnace, and cool with through-wall units, the failures are at circulators, zone valves, igniters, capacitors and drains rather than at the boiler itself.
Service Area: The Bronx
We repair heating and cooling equipment across the Bronx, on both sides of the Bronx River, in the neighborhoods below and the rest of the borough around them, from Crotona Park to the streets along the Cross Bronx Expressway.
- West FarmsZIP 10460. Five and six story tenement buildings, older multi-unit homes and newer townhouses between the Bronx River and Southern Boulevard. In a walk-up on steam, cold radiators usually trace to stuck vents or a main that lost its pitch.
- Crotona Park EastZIP 10459 and 10460. Rebuilt tenements, attached townhouses and the ranch houses along Charlotte Street. Houses with their own hot water boiler or gas furnace run into circulator, zone valve and igniter failures.
- East TremontZIP 10460 east of Prospect Avenue, and 10457. Mostly five and six story walk-ups plus newer apartment buildings. Banging steam pipes and cold top-floor radiators point to water lying in the mains and clogged vents.
- Van NestZIP 10460 west of Unionport Road, and 10462. Single-family homes of many styles and some tenements. An older house that kept its cast iron radiators and changed boilers can heat unevenly until the radiators and piping are balanced.
